Experience powerful disinfection with our Chlorhexidine Bigluconate 0.5% water-alcohol solution, packaged in a convenient 150ml spray bottle. This highly effective disinfectant is your go-to solution for sanitizing skin, medical instruments, and various surfaces.
</section> <section>Apply 3ml of the solution to your hands and rub into the skin until dry, ensuring complete coverage within 30 seconds.
Prior to application, wash hands and forearms thoroughly with soap and running water for at least 2 minutes. Dry with a sterile gauze pad. Apply 2.5ml of the solution twice, rubbing into hands and forearms until dry. Total application time: 5 minutes. Wear sterile gloves only after the solution has completely dried.
Thoroughly wipe the skin twice with separate sterile gauze pads, generously soaked with the solution. Allow a 2-minute contact time after application. Patients should shower or bathe and change linens the day before surgery.
For injections, including vaccination sites, wipe the skin with a sterile cotton swab generously moistened with the solution. Allow a 30-second contact time. For puncture sites, such as joint punctures or catheter insertions, generously irrigate the skin until fully moistened, followed by a 30-second contact time.
Thoroughly wipe the outer surface of worn gloves with a sterile cotton or gauze swab, generously moistened with at least 3ml of the solution. Allow at least 1 minute for disinfection. Ensure the glove surface is completely dry.
(Ideal for healthcare facilities, beauty salons, hairdressers, nail and pedicure studios, etc.) Immediately after use, fully immerse instruments in the solution. Remove visible contaminants with tissue wipes before immersion. Dispose of used wipes after disinfection. Fill all channels and lumens of instruments with the solution, avoiding air bubbles. Repeatedly pump the solution through channels with a syringe or other device, alternating with air, until all biological contaminants are removed. Disassemble instruments with multiple parts before immersion. For instruments with locking mechanisms, immerse them in an open position, performing a few working movements to ensure solution penetration into hard-to-reach areas. The solution layer above the instruments should be at least 1 cm thick. After a 5-minute disinfection period, remove instruments and rinse with potable running water for at least 1 minute. Pay close attention to rinsing channels (using a syringe or suction device).
Transportation by land is permitted according to applicable cargo regulations at temperatures between 0°C and +30°C. In case of accidental spills, collect the liquid in a container for proper disposal.
</section> <section>Store in the manufacturer's tightly sealed packaging at temperatures from 0°C to +30°C. Keep away from heat and ignition sources. Protect from direct sunlight. Store separately from medications and out of reach of children.